Eco Resist
For thermal load, chemical attack and antistatic floors. 700 °C, pH 3 to 14, DIN EN 61340-5-1.
Where it may be used
Indoor and outdoor, as stated on this system's own data sheet. Use elsewhere is not covered by that sheet.
Application temperature: +2 °C.
Thickness range: 2 to 50 mm.
Substrate must be sound and free of loose material, with a pull-off strength of at least 1.5 N/mm². The chemistry is consistent; what the floor becomes depends on the substrate, the specification and the applicator.
Declared for this system
700 °C is an intermittent exposure figure: the floor takes a hot spill or a passing flame without breaking down. It is declared for Eco Resist only and is not carried by the other industrial floor systems.
VOC- and APEO-free is declared for Eco Sil, Eco Flex All In One and Eco Shield only, so it is not claimed here. BREEAM, DGNB and LEED contribution is documented per project, not per range.
Data sheet figures
| Property | Value | Standard |
|---|---|---|
| Strength class | CT-C50-F10 | DIN EN 13813 |
| Compressive strength | approx. 50 N/mm² | DIN EN 13813 |
| Flexural strength | approx. 10 N/mm² | DIN EN 13813 |
| Abrasion resistance | A12 | DIN EN 13813 |
| Thermal resistance | 700 °C | — |
| Chemical resistance | pH 3 to 14 | — |
| Waterproof | 2.5 bar | — |
| Antistatic | yes | DIN EN 61340-5-1 |
| Slip resistance | R 10, R 13-V8 | — |
| Application thickness | 2 to 50 mm | — |
| Consumption | approx. 1.8 kg/m² per mm | — |
| Mixing ratio | 4.25–4.4 L water / 25 kg powder | — |
| Processing temperature | min. +2 °C, max. +35 °C | — |
| Walkable | after 6 hours | — |
| Fully loadable | 4 days (7 days exterior) | — |
| Emission class | EMICODE EC1PLUS | GEV |