Certifications, test reports and declarations — all on the proof hub.
Silicate Systems
Contact
← All systems
Industrial floors

Eco Resist

For thermal load, chemical attack and antistatic floors. 700 °C, pH 3 to 14, DIN EN 61340-5-1. 


Where it may be used

Indoor and outdoor, as stated on this system's own data sheet. Use elsewhere is not covered by that sheet.

Application temperature: +2 °C.

Thickness range: 2 to 50 mm.

Substrate must be sound and free of loose material, with a pull-off strength of at least 1.5 N/mm². The chemistry is consistent; what the floor becomes depends on the substrate, the specification and the applicator.


Declared for this system
EMICODE EC1PLUS — very low emission700 °C intermittent thermal resistanceAntistatic, DIN EN 61340-5-1

700 °C is an intermittent exposure figure: the floor takes a hot spill or a passing flame without breaking down. It is declared for Eco Resist only and is not carried by the other industrial floor systems.

VOC- and APEO-free is declared for Eco Sil, Eco Flex All In One and Eco Shield only, so it is not claimed here. BREEAM, DGNB and LEED contribution is documented per project, not per range.


Data sheet figures
Eco Resist. Figures from the published technical data sheet.
PropertyValueStandard
Strength classCT-C50-F10DIN EN 13813
Compressive strengthapprox. 50 N/mm²DIN EN 13813
Flexural strengthapprox. 10 N/mm²DIN EN 13813
Abrasion resistanceA12DIN EN 13813
Thermal resistance700 °C—
Chemical resistancepH 3 to 14—
Waterproof2.5 bar—
AntistaticyesDIN EN 61340-5-1
Slip resistanceR 10, R 13-V8—
Application thickness2 to 50 mm—
Consumptionapprox. 1.8 kg/m² per mm—
Mixing ratio4.25–4.4 L water / 25 kg powder—
Processing temperaturemin. +2 °C, max. +35 °C—
Walkableafter 6 hours—
Fully loadable4 days (7 days exterior)—
Emission classEMICODE EC1PLUSGEV

Documents

/systems/eco-resist